VVAJRAConcrete · Nagpur

Quality & certifications

Every block we ship
is documented.

Six certifications, six in-line QC checkpoints, third-party testing every quarter. Every pallet leaves the plant with a batch number you can trace back to the fly-ash truck that delivered the raw material.

100%

Pallets QC-stamped

0.6%

Avg. dimensional variance

4.0

N/mm² avg. strength

0

Customer-rejected pallets 2025

Certifications · 6

Every standard that matters. Held current.

IS 2185 (Part 3)

Bureau of Indian Standards

Compliance to the Indian Standard for AAC blocks. Third-party tested at National Test House Mumbai every quarter.

Valid through Dec 2028

ISO 9001:2015

Quality Management System

Plant-wide QMS audited annually by TÜV SÜD. Covers procurement, batching, autoclave, QC, dispatch.

Re-certified Mar 2026

IGBC Certified

Green Pro Eco-Label

VAJRA AAC qualifies for up to 18 IGBC credits in LEED and IGBC Green Building rating systems.

Re-validated 2026

IS 3809

Fire Resistance

4-hour fire rating for 200 mm wall, tested at CBRI Roorkee. Reports available on request.

Last tested Dec 2025

IS 3346

Thermal Conductivity

Guarded hot-plate test confirms 0.21 W/m·K — among the lowest values in the Indian AAC market.

Last tested Dec 2025

IS 6441

Drying Shrinkage

Tested per IS 6441 Part 2. Our blocks consistently come in below 0.035% — below the 0.05% limit.

Last tested Feb 2026

Need a certificate copy?

We send PDFs of all six within an hour, including the latest test reports.

Browse downloads

In-plant QC · 6 checkpoints

Six gates between raw material and your truck.

An external certificate is only as good as the daily routine behind it. Here's every QC step a block passes through before it leaves Hingna.

01

Raw material gate test

Every fly-ash truck sampled for moisture, fineness and Class F compliance before unloading. ~3% load rejection.

02

Batch chemistry log

Each batch's cement / fly-ash / lime / aluminium ratio digitally logged with a 7-year retention policy.

03

Pre-autoclave density check

Green-cake density measured before autoclaving. Target 600 kg/m³ ±2%. Out-of-spec cakes scrapped immediately.

04

Post-autoclave dimensional QC

Every cured block measured on length, height, thickness — wire-cut to ±2 mm tolerance per IS 2185.

05

Daily compressive strength

Random blocks from each shift pulled for compressive testing per IS 2185. Results logged and published monthly.

06

Pallet stamp + traceability

Every pallet stamped with batch code traceable back to raw-material source. Full chain-of-custody on request.

In-house lab

A laboratory inside the plant. Always staffed.

Our 180 m² QC lab runs the daily strength, density and dimensional tests on every shift's production. Two full-time QC engineers report directly to the Technical Director — never to plant operations — so there's no incentive to pass a borderline batch.

Latest published QC summary

May 2026 · all shifts

Compressive strength (avg)

Target ≥ 3.0

4.12 N/mm²
Density (avg)

Target 600 ±2%

601 kg/m³
Dimensional variance

Limit ±2 mm

±1.4 mm
Drying shrinkage

Limit 0.05%

0.034%
Thermal conductivity

Lower is better

0.21 W/m·K
Loss on rejection

Industry avg ~3%

0.7%